Southbend StratoSteam STRE-5D Manuel d'utilisateur Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
SERVICE STRATOSTEAM ELECTRIC COUNTERTOP STEAMER
PAGE 26 OF 56 OWNERS MANUAL 1189951 (10/08)
Figure 15
Power Switch Check
L1 L2 L3
14
25
36
Connector
PL1
(socket half)
Contactor
L1 L2 L3
14
25
36
Connector
PL1
(socket half)
14
25
36
Connector
PL1
(socket half)
Test-Lead Positions
for Steps 5 to 7
Test-Lead Positions
for Step 8
Test-Lead Positions
for Step 9
Continuity
No Continuity
Continuity
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side panel.
3. Turn control lever from OFF to ON and then from ON to OFF while looking to see that the power switch is
properly actuating when the lever moves.
4. Disconnect the connector (PL1) that connects the control-panel component wires to the wiring harness.
5. As shown above, place one test lead on terminal L1 of the contactor and the other test lead in position 1 of
connector PL1 (the socket half, which is wired to the control panel).
6. Check for continuity with control lever in OFF position (there should not be continuity).
7. Check for continuity with control lever in ON position (there should be continuity).
8. Repeat steps 5 through 7 with one test lead on terminal L3 of the contactor and the other test lead in position
2 of connector PL1 (as shown above).
9. Place one test lead on PL1 position 1 and the other test lead on PL1 position 2 (as shown above). Check for
continuity with control lever in the ON position (there should not be continuity).
10. If continuity checks are incorrect, replace power switch.
11. Reconnect lead wires.
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 55 56

Commentaires sur ces manuels

Pas de commentaire